BXTKM - LOCQUIC ACTIVATOR 707 (AEROSOL), 70715
- MSDS: BXTKM
- Manufacturer: LOCTITE CORP
- Product Name: LOCQUIC ACTIVATOR 707 (AEROSOL), 70715
- National Stock Number: 8040-01-326-6209
Product Identification
Product ID:LOCQUIC ACTIVATOR 707 (AEROSOL), 70715
MSDS Date:01/01/1994
FSC:8040
NIIN:01-326-6209
MSDS Number: BXTKM
Responsible Party
NEWINGTON, CT 06111
US
Emergency Phone: 203-278-1280
Info Phone: 203-278-1280
Preparer: STEPHEN REPETTO
Cage: 7K128
Contractor
Telephone: 860-571-5100
Cage: 05972
Ingredients
7%,
CAS: 71-55-6
RTECS: KJ2975000
Fraction By Weight: 80-85%
OSHA PEL 350 PPM
ACGIH TLV: 350 PPM
EPA Report Quantity: 1000 LBS
DOT Report Quantity: 1000 LBS
BUTANAL-ANILINE CONDENSATE
CAS: 9003-37-6
Fraction By Weight: 10-15%
OSHA PEL N/K
ACGIH TLV: N/K
CARBON DIOXIDE
CAS: 124-38-9
RTECS: FF6400000
Fraction By Weight: 2-5%
OSHA PEL 5000 PPM
ACGIH TLV: 5000 PPM
8%.
CAS: 75-65-0
RTECS: EO1925000
Fraction By Weight: 1-3%
OSHA PEL 100 PPM
ACGIH TLV: 100 PPM
2.2%,
CAS: 109-87-5
RTECS: PA8750000
Fraction By Weight: 1-3%
OSHA PEL 1000 PPM
ACGIH TLV: 1000 PPM
9.16%; 110 GRAMS
RTECS: 9999999VO
OSHA PEL N/K
ACGIH TLV: N/K
Hazards
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:TOX:MOD VIA INGEST. EYE IRRIT. EST
DERMAL LD50 >2000 MG/KG. CHLOROCARBON MATLS HAVE PRDCED SENSIT OF
MYOCARDIUM TO EPINEPHRINE IN LAB ANIMALS & COULD HAVE SIMILAR EFT
IN HUMANS. ADRENOMINETICS (E.G. E PINEPHRINE) MAY BE
CONTRAINDICATED EXCEPT FOR LIFE-SUSTAINING USES IN HUMANS
ACUTELY/CHRONICALLY (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZS:EXPOSED TO CHLOROCARBONS . SIGNS &
SYMPS OF OVEREXP:HEADACHE, NAUSEA, DIZZINESS. NARCOSIS AT HIGH
CONCENTRATIONS.
Medical Cond Aggravated by Exposure:ING 1:CNS, LIVER, HEART DISEASE,
ALCOHOLISM, SKIN DISORDERS, EYE PROBLEMS, RESPIRATORY PROBLEMS.
First Aid
First Aid:INGESTION:DO NOT INDUCE VOMITING. KEEP INDIVIDUAL CALM.
OBTAIN MEDICAL ATTENTION. INHALATION:REMOVE TO FRESH AIR. IF
SYMPTOMS PERSIST, OBTAIN MEDICAL ATTENTION. SKIN:FLUSH WITH WATER.
EYES:FLUSH THORO UGHLY WITH WATER FOR AT LEAST 15 MINUTES. OBTAIN
MEDICAL ATTENTION.
Fire Fighting
Flash Point Method:TCC
Flash Point:NONE
Lower Limits:SEE INGS
Upper Limits:SEE INGS
Extinguishing Media:CARBON DIOXIDE, FOAM, DRY CHEMICAL.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED PRESSURE DEMAND SCBA
& FULL PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:THERMAL DECOMP PRODS MAY INCLUDE HCL &
PHOSGENE CANS MAY RUPTURE IN FIRES. HAZ PRODS FORMED BY
FIRE/THERMAL DECOMP:TOXIC CHLORIDES. COMPRESSED (SUPP DATA)
Accidental Release
Spill Release Procedures:ALLOW TO EVAPORATE WITH GOOD VENTILATION. SOAK
UP RESIDUE IN AN INERT ABSORBENT.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:STORE BELOW 110F. AVOID PROLONGED
BREATHING OF VAPORS.
Other Precautions:NO SMOKING IN AREA OF USE. DO NOT USE IN THE GENERAL
VICINITY OF ARC WELDING, OPEN FLAMES OR HOT SURFACES. HEAT AND/OR
UV RADIATION MAY CAUSE THE FORMATION OF HCL AND/OR PHOSGENE .
Exposure Controls
Respiratory Protection:USE NIOSH/MSHA APPROVED RESPIRATOR APPROPRIATE
FOR EXPOSURE OF CONCERN .
Ventilation:PROVIDE ADEQUATE LOCAL VENTILATION TO MAINTAIN VAPOR
CONCENTRATION BELOW TLV.
Protective Gloves:RUBBER/PLAXTIC GLOVES RECOMMENDED.
Eye Protection:ANSI APPROVED CHEM WORKERS GOGGS .
Other Protective Equipment:NONE SPECIFIED BY MANUFACTURER.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
EXPLO HAZS:GASES:CARBON DIOXIDE.
Chemical Properties
Boiling Pt:B.P. Text:175F,79C
Vapor Pres:100
Vapor Density:4.5
Spec Gravity:1.20 @ 80F
Solubility in Water:SLIGHT
Appearance and Odor:BROWN LIQUID WITH A SHARP ODOR.
Stability
Stability Indicator/Materials to Avoid:YES
SOLVENTS MAY REACT VIOLENTLY WITH ALUMINUM ON PROLONGED CONTACT.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:NONE. HCL, PHOSGENE .
Disposal
Waste Disposal Methods:DISPOSAL MUST BE I/A/W FEDERAL, STATE & LOCAL
REGULATIONS . FOLLOW EPA AND LOCAL REGULATIONS FOR DISPOSAL OF
CHLORINATED HYDROCARBONS UNDER PRESSURE.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.